Datasheet
Air / Gasfilter-Separator TYPE LGFA |
| |
|
| |
Flowrate
Vn at 10 bar: appr. 1.734 to appr. 126.782 m³/h. |
| |
 |
| Removal
of solid impurities and precipitation of condensate, also
in mist form, from air or gas streams. |
| Fractional
separation efficiencies: |
| (solid
impurities) |
1
µm zu 98,90% |
3
µm zu 99,90% |
| >5
µm zu 99,99% |
| (liquid
impurities) ) |
1
µm zu 98,60% |
3
µm zu 98,90% |
| >5
µm zu 99,97% |
| pressure
drop under clean conditions: <100mbar |
| max.
allowable pressure drop: 1,4 bar |
| Bursting
prtessure: 3 bar |
| Boiler
plate, grain refined or austenitic steel, shell depending
on requirements. Boiler plate and grain-refined shell are
sandblasting inside and outside acc. to SA 21/2, finished
inside with two layers of benzene-resistant coating, outside
with one layer. Fittings are of 1.4514 Silumin or cadmium-plated
steel. |
|
| Separator
with coalescer-elements |
|
| The
vessels are manufactured and inspected acc to the German AD-Merkblatt
by an independant inspection agency. Pressue vessel calculation
to teh ASME code on requirement. |
The coalescer
cartridges are made of impregnated cellulose and glass fibre
providing a combined surface and deep action and performs
the following two functions:
| a)
Removal of solid impurities down to 1 micron. |
b)Coalescence
of the fine condensate droplets to larger ones and their precipitation. |
| The
air or gas stream enters the vessel through the inlet nozzle.
The first larger quantities of the condensate and solid impurities
are separated at the inlet buffle in the lower part of the
vessel. Finest solid impurities, droplets of condensate and
mist of condensate are flowing to the upper part of the vessel
passing through the coalescer elements from the inner tube
to the outside. Solid impurities down to sizes of one micron
are retained by the filter. The last small amounts of condensate
are coalescing to small droplets and are flowing down into
the upper collecting chamber of the vessel. The purified air
or natural gas is leaving the vessel through the outlet nozzle. |
|
 |
| Additionals: |
| Quick opening
closure, 100% x-raying, pressure vessel calculation acc. to ASME
and other various accessories can be ordered. |
|